Flow measurement in district heating systems
JUMO application example
Success story
Quest
In Austria, the exhaust gas treatment system filters more than 90% of nitrogen and sulfur dioxide and almost 100% of exhaust dust. The high efficiency of the installation is due in part to the use of heat exchangers. In the condensing tubes of a heat exchanger in a power plant, flow and temperature must be measured continuously. These two variables determine the efficiency of the heat exchanger, but the ultrasonic flow meters that were initially used did not perform well in this application.
Some flowmeters require a very long run of pipe—up to 50 nominal pipe dimensions—upstream of the measurement point to stabilize the flow after passing through bends, valves, or restrictions. This has a significant impact on the size of systems. The customer requested a flow meter that could be used in more compact installations.
In addition, water in the process may have a conductivity of 6,4 µS/cm and a temperature of 65 °C. For conductivity <20µS/cm, magnetic inductive measurement usually requires special devices that have a stronger magnetic field and a higher sampling frequency to ensure reliable measurement.
Solution Approach
The plant operator now uses the magnetic inductive flow meter from JUMO to measure flow. The reason is that with JUMO flowTRANS MAG S01 the required distance between bends, valves and restrictions and the flow meter is only 3 times the nominal pipe size.
In addition, the JUMO flowTRANS MAG S01 has very high electromagnetic field coils as standard, which provides stable measurement at conductivity <20 µS/cm and meets high customer requirements without the need for significantly more expensive measurement solutions.
Project results
The diagnostic function allows you to quickly detect unwanted deposits on the electrode. This type of contamination is common when the flowmeter is operated in hot water.
Flexible placement without a long upstream pipe, simple configuration options and excellent measurement results with low conductivity fluids ultimately led the customer to select the JUMO flowTRANS MAG S01. flowmeter.
Do you have a similar task?
Manufacturer JUMO expertise
We have measurement and control solutions that are used in a variety of machines and systems.
All applications