Logo JUMO

JUMO RTD temperature probes

Paired temperature sensors for heat meters (type DS/DL)

Paired RTD temperature probes for temperature measurement in closed pipeline systems. Pairing according to MID and MessEG. Comply with DIN EN 1434, AGFW FW 202 and FW 211. Pt100, Pt500 or Pt1000 sensor. Stainless steel protective fitting. PVC, polyurethane, TPE or silicone cable. 2- or 4-wire circuit. IP65 protection. Operating temperature from 0 to 180 °C.

  • Certification according to MID
  • DIN EN 1434, AGFW FW 202 and FW 211
  • Compliant with MessEG and MID standards

Type 902455

Model: in stock

Statuses are based on JUMO data. Please contact IMAGO to confirm availability in Kazakhstan and delivery times.

JUMO data as of 5 November 2026
Send request
Paired temperature sensors for heat meters (type DS/DL)

Technical data

General technical data

Connection
Ferrules
Connecting cable
PVC, polyurethane, TPE, silicone, sheathed or unsheathed
Process connection
Type DS: M10 × 1 threaded connection, brass, to DIN EN 1434; type DL: G 1/4 or G 1/2 thread, stainless steel
Protective tube
Stainless steel
Temperature sensor
Pt100, Pt500 or Pt1000
Temperature
0 to 120 °C (cooling) / 0 to 180 °C (heating)
Expand tableCollapse table
Minimum immersion depth
Type DS: 15 mm, type DL: 30 mm
Immersion length
Type DS: 25 - 60 mm, type DL: 60 - 280 mm
Protection rating
IP65
Optional
Two- or four-wire connection
Features
MID type examination certificate and domestic approval for use as replaceable temperature probes in combined heat and cold meters. Comply with DIN EN 1434, AGFW FW 202 and FW 211; pairing and declaration of conformity according to MessEG and MID. Production certified under module D of MID (CE and metrology marking).
Accessories
Ball valves (recommended installation components): see data sheet 902442

Data sheet

Technical specification source — JUMO

Video

Documentation

  • Basics

    Connection diagrams for RTD temperature probes and Thermocouples

    PDF · English · 90000200T10Z001K000.pdf
  • General information

    Verpackungsanweisung für Rücklieferungen von Temperaturfühlerpaaren an JUMO

    PDF · German / English · VDK_PD90-MG_Rücklieferung von Temperaturfühlerpaaren_DE-EN.pdf
  • Declaration of conformity

    Declaration of Conformity nach MessEG (DE-15-M-PTB-0050, Revision 1)

    PDF · German · DE-015-DE-15-M-PTB-0050 - Rev. 1 (2025).pdf
  • Declaration of conformity

    Declaration of Conformity nach MessEG (DE-15-M-PTB-0052, Revision 3)

    PDF · German · DE-017-DE-15-M-PTB-0052 - Rev. 3 (2025).pdf
  • General information

    Liste ausgesprochener Duldungen für Bestandstauchhülsen

    XLSX · German · DL_TH_2023-11-20.xlsx
  • General information

    Information zur Identifikation von Bestandstauchhuelsen

    PDF · German · Information zur Identifikation von Bestandstauchhuelsen.pdf
  • General information

    Information der Hessischen Eichdirektion Verlängerung Übergangsphase Bestandstauchhülsen

    PDF · German · Information der Hessischen Eichdirektion Verlängerung Übergangsphase Bestandstauchhülsen.pdf
  • Certificate

    Compliance China RoHS Compliance-20 – JUMO HEATtemp

    PDF · German / English / Chinese · 902455 China RoHS Table- .pdf
  • Operating manual

    Temperature probe for combined cold/heat meters – 902428/50, 902428/51, 902438/50, 902438/51, 902455/50, 902455/51, 902465/50, 902465/51

    PDF · English · 90245550T90Z001K000.pdf
  • Operating manual

    Temperature probes for thermal energy measuring devices – 902428/20, 902428/70, 902428/71, 902455/20, 902455/70, 902455/71

    PDF · English · 90245520T90Z001K000.pdf
  • Type-examination certificate

    902455/30, 902455/40, 902465/30

    PDF · German / English · DE-15-M-PTB-0050 Rev. 1.pdf
  • Type-examination certificate

    902455/20, 902455/50, 902455/51, 902455/70, 902455/71, 902465/50, 902465/51

    PDF · German / English · DE-15-M-PTB-0052 Rev. 3.pdf
  • Basics

    Installation, Inbetriebnahme und Wartung von Widerstandsthermometern und Thermoelementen

    PDF · German · JUMO - Installation, Inbetriebnahme und Wartung von Widerstandsthermometern und Thermoelementen.pdf
  • Declaration of conformity

    EC Declaration of Conformity – WKZ-WTH mit AL-DS - DL-PTB - MID

    PDF · German / English / French · EUDoC_DE_902455_WKZ-WTH mit AL-DS - DL-PTB - MID_CE 1119.pdf
  • Data sheet

    JUMO HEATtemp

    PDF · English · 90245500T10Z001K000.pdf
  • Operating manual

    Temperature probes for combined cold/heat meters – 902428/30, 902428/40, 902438/30, 902438/32, 902455/30, 902455/40, 902465/30, 902465/32

    PDF · English · 90242830T90Z001K000.pdf
  • Ordering information

    Ordering data 902455

    PDF · English · orderdetails_902455_en.pdf

Need help?

Enquiries and quotations

We will help with your project and prepare a quotation based on your requirements.

Sales · IMAGO

Aliya Kamenova
Sales Manager

+7 777 030 8848 Request a quote

Customer Service

We will help resolve technical questions and advise on equipment commissioning.

Customer Service · IMAGO +7 708 327 8770 Contact service

Privacy Settings

This preview uses local files. Analytics services JUMO are not connected.